A New Patient Asked to Move Within the First Hour Because of a Lingering Smell: When a Phitsanulok Private Hospital Had to Speed Up Room Turnover After Discharge and the Ozone Generator

Last updated: 23 Nov 2026  |  26 Views  | 

A New Patient Asked to Move Within the First Hour Because of a Lingering Smell: When a Phitsanulok Private Hospital Had to Speed Up Room Turnover After Discharge  and the Ozone Generator

A New Patient Asked to Move Because of a Lingering Smell — the Lesson for Post-Discharge Room Turnover

A room cleaned to standard, but a lingering odour leaves the next patient uneasy from the first step

A call bell in the first hour

Wanna heads housekeeping at a 150-bed private hospital in Phitsanulok, leading more than forty staff responsible for everything from the emergency department to inpatient wards and the private rooms that are a key source of hospital revenue.

One Tuesday afternoon, the charge nurse on the seventh floor called. A woman in her sixties, just admitted to a private room, had pressed the call bell within her first hour, saying the room smelled strange — like a wound and mustiness — and asking to move. The room had just been vacated by a bedbound patient with pressure ulcers who had stayed more than a month, and housekeeping had cleaned it to standard that morning.

It wasn't the first time. Over three months there had been several odour complaints in rooms after long-stay discharges, sometimes requiring patients to move — wasting available beds and adding to nurses' workload.

"The room is clean to standard," Wanna told her team, "but patients don't judge it by test results. They judge it with their noses."

Why odours linger after long-stay patients

  • Chronic wounds and secretions: pressure ulcers or infected wounds have distinctive odours whose compounds can soak into porous materials.
  • Urine and faeces from patients with incontinence may splash or seep into floor joints, bed legs and bathroom grout.
  • Absorbent materials: curtains, relatives' sofas, chair cushions and some ceiling tiles.
  • Air conditioning: in-room filters and vents can hold odours.
  • Rooms kept closed to control temperature, so odours aren't ventilated.
  • Limited turnover time: sometimes only two to three hours between discharge and the next admission.

The impact on patients and the hospital

  • Unease for new patients: odours make patients worry about cleanliness and infection, even when the room has been cleaned and disinfected.
  • Nausea and poor appetite: some patients are very sensitive to smells, especially those on chemotherapy or pregnant women.
  • Lower satisfaction scores: odour complaints appear in surveys and online reviews.
  • Room moves waste available rooms, add nursing work and disrupt bed management.
  • Private-hospital reputation: patients choose hospitals on overall experience, not treatment alone.

Why the existing routine wasn't enough

  • Standard surface cleaning and disinfection: essential and correct, but it didn't address odours absorbed into soft materials and AC vents.
  • Scented air fresheners masked odours briefly, and strong fragrances can make some patients dizzy or trigger reactions.
  • Activated charcoal or odour gels did little in a large room in limited time.
  • Opening windows: most patient-room windows open only slightly for safety.
  • Curtains and AC not cleaned every time, because it takes too long.

Wanna consulted the hospital's infection-control team, and they agreed to redesign the post-discharge procedure for long-stay rooms and add an odour step that could be done safely in empty rooms.

The solution: an Ozone Generator as a supplementary step

After consulting World Health Disinfection and the infection-control team, the hospital introduced an Ozone Generator as a supplementary step after standard surface cleaning and disinfection — only in empty rooms vacated by long-stay patients or with odour problems.

Ozone is a strongly oxidising gas that spreads throughout a room, reaching curtains, cushions and corners. It helps break down odour-causing compounds and helps reduce microbes on surfaces exposed at the right concentration and time. After the cycle and ventilation, ozone breaks down back into oxygen.

  • Tackles odour at the source, not with fragrance.
  • Reaches soft materials and corners that can't be wiped.
  • Timer operation in the gap between patients.
  • No chemical smell once ventilation is complete.
⚠️ Safety first
Ozone at room-treatment concentrations is harmful to breathe. Use it only in rooms with no patients, relatives or staff. Close the door, post a no-entry sign, close vents connecting to other rooms where possible, set the timer per the manual and ventilate fully before reopening. Never use it in occupied multi-bed wards or as an air purifier. Ozone treatment does not replace cleaning and disinfection to the hospital's infection-control standards. Remove ozone-sensitive medical equipment and rubber items before treatment.

10 reasons hospitals and care facilities use ozone as a supplementary step

  1. Reduces lingering odours absorbed into curtains and relatives' sofas.
  2. Reaches every corner, including in-room AC vents.
  3. No need for scented sprays that may bother patients.
  4. Works while rooms are empty, on a timer.
  5. Helps reduce surface microbes as an extra layer.
  6. Fewer room moves, improving bed management.
  7. Higher satisfaction: patients feel at ease from the first step.
  8. Portable, rotating between wards.
  9. Other uses: soiled-linen rooms, staff rest rooms and ambulances when unoccupied.
  10. Expert support: WHD advises on unit size, cycle times and safety alongside infection control.

The new post-discharge procedure for long-stay rooms

  1. Strip all linen and textiles — sheets, pillowcases, blankets and curtains — and send them through the hospital's soiled-linen system.
  2. Discard single-use items and infectious waste as required.
  3. Remove organic soiling from floors, bed legs, bed rails and the bathroom, scrubbing grout and joints where residue may have seeped.
  4. Disinfect surfaces with the hospital's specified disinfectant for the labelled contact time: bed, rails, overbed table, remote, call bell, door handles and bathroom.
  5. Check the patient mattress: if the cover is torn or fluid has seeped in, report it for replacement.
  6. Clean in-room AC filters and vents per engineering's schedule and after every odour-problem patient.
  7. Ozone-treat the empty room: remove ozone-sensitive equipment, close the door, post the sign and set the timer per the manual.
  8. Ventilate for the specified time before entering.
  9. Hang fresh curtains and make up the room.
  10. Final inspection: the housekeeping supervisor checks by sight and smell and signs off before returning the room to the ward.

Fitting the procedure into bed management

Time was the biggest obstacle, so Wanna coordinated with bed management and charge nurses:

  • Flag rooms needing the special procedure: nurses give advance notice when a long-stay patient or one with an odorous wound is close to discharge.
  • Allow extra turnover time for these rooms; bed management won't admit a new patient immediately.
  • Rotate available rooms, using ready rooms first while those needing ozone are being treated.
  • Treat overnight for evening discharges, so rooms are ready the next morning.

Before and after

❌ Before
  • Surfaces cleaned but odour remained
  • Scented sprays to mask smells
  • Curtains and AC not cleaned every time
  • New patients asking to move
  • No advance notice of high-risk rooms
  • Complaints in satisfaction surveys
✅ After
  • A dedicated post-discharge procedure for long-stay rooms
  • Curtains changed and AC cleaned
  • Ozone in empty rooms as a supplementary step
  • Full ventilation before handover
  • Advance coordination with bed management
  • Odour complaints sharply reduced

Training housekeepers to use the unit safely

  • Trained staff only: a list of authorised operators is posted in the equipment room.
  • A pre-treatment checklist: confirm nobody is in the room or bathroom; remove medical equipment, plants and ozone-sensitive items; close the door and post the sign.
  • Coordinate with the ward nurse every time, so nobody enters by mistake.
  • No entry during treatment: if entry is essential, stop the unit from outside and wait for ventilation first.
  • Log every session: room number, start and end times, ventilation time and operator.
Powered by MakeWebEasy.com