The Pharmacist Who Had to Close for Five Days in Peak Flu Season — and the Invisible Germ Lesson Behind the Counter
Pharmacies are the front line of community health. Protecting them with after-hours UV-C is essential.
A "temporarily closed" sign for the first time in twelve years
On a Wednesday morning in early July, regular customers of a small pharmacy near Bang Yai market in Nonthaburi stood puzzled in front of a closed metal shutter. Taped to it was a handwritten A4 sheet: "Sorry, closed until Monday. Pharmacist unwell." In twelve years of business, nobody had ever seen such a sign.
Pharmacist Nantana — "Dr. Nan" to her customers — lay upstairs with a fever close to 39°C, aching all over and coughing until her chest hurt. A test confirmed influenza. She thought back to the previous week, when dozens of customers a day came in for fever reducers and cough medicine. Many coughed over the counter without covering their mouths. Some brought feverish toddlers, queueing shoulder to shoulder in a shop of less than twenty square metres.
What worried Dr. Nan more than her own illness was that the shop had closed exactly when the community needed it most. Older customers who relied on her for chronic-disease medicines had to travel further to other pharmacies, and her only assistant was beginning to complain of a sore throat.
Pharmacies: where sick people gather without meaning to
For many people, the community pharmacy is the first stop in the health system. When fever, cough or sore throat begins, most visit the pharmacy near home before going to hospital. That means during flu season, pharmacies are among the places with the highest concentration of people carrying respiratory infections — while most are small shophouses with closed doors, air conditioning and limited ventilation.
Influenza, COVID-19 and many other respiratory viruses spread through droplets from coughing, sneezing and talking. Small droplets can linger in the air of a closed room for some time. Larger droplets settle on counters, medicine baskets, card machines, pens and door handles — surfaces both customers and the pharmacist touch hundreds of times a day.
Vulnerable people who walk into pharmacies every day
- Older adults collecting medicines for blood pressure, diabetes or heart disease. Influenza can lead to complications such as pneumonia.
- Young children brought along by parents buying medicine or formula.
- Pregnant women buying prenatal vitamins, a group in whom influenza can be more severe.
- People with chronic illnesses, including lung and kidney disease, or those on immunosuppressants.
- Pharmacists and staff, exposed to sick customers all day, every day, all season.
Influenza differs from a common cold in that it often starts suddenly with high fever, severe muscle aches and exhaustion. It can keep someone in bed for days, followed by a period of recovery. For a pharmacy with only one pharmacist, that means closing.
The cost of a single illness
Once she recovered, Dr. Nan calculated the damage from five days of closure. The numbers convinced her it must never happen again.
- Five full days of lost revenue in peak season — the rainy season is the year's highest period for fever, cough and mask sales.
- Regular customers moved elsewhere; some older customers switched to large chain pharmacies and didn't return.
- Fixed costs kept running: rent, staff wages, electricity for the medicine and vaccine fridges.
- Some stock expired that had been planned to sell during that period.
- Team health: the assistant was sick for three more days, so Dr. Nan reopened alone before fully recovering.
- Community confidence: someone in the neighbourhood LINE group wrote, "Went to the pharmacy and came back with a cold" — even though nobody could prove where it was caught.
Dr. Nan realised that for a small pharmacy, the pharmacist's health is the business's most important asset, and preventing infection in the shop is not a luxury.
Existing measures with gaps
Dr. Nan had never neglected cleanliness, but a careful review revealed gaps.
1. Wiping the counter with alcohol twice a day
This only helps the surfaces wiped at that moment. Dozens of customers re-touch them throughout the day, and wiping doesn't cover shelves, medicine boxes and hard-to-reach corners.
2. Running fans
A shophouse with windows on one side circulates air inside rather than exchanging it with fresh air.
3. Plastic screens
They block some direct droplets, but fine aerosols drift around them, and the screens themselves become another surface to clean.
4. Spraying disinfectant into the air
Most sprays are designed for surfaces. Spraying them into the air has limited effect, and chemical smells may affect products on the shelves.
5. No whole-room disinfection overnight
After closing, germs accumulated during the day remained on surfaces and in the air until morning — exactly when Dr. Nan arrived first to restock the shelves.
UV-C light: a disinfection technology hospitals have used for years
A senior pharmacist friend working in a hospital told Dr. Nan that many hospitals use ultraviolet-C (UV-C) light to disinfect patient rooms and operating theatres after cleaning. For a small shop, a suitable unit is the MASTER UV-C 996 sterilizer, a 38-watt disinfection lamp that combines UV-C light with ozone.
UV-C light at germicidal wavelengths damages the genetic material of microorganisms — bacteria, viruses and fungi — so they can no longer reproduce. The light acts on surfaces it reaches directly and on the air around the unit, while the ozone it generates disperses through the room, helping to reach areas the light cannot and reducing musty odours.
The principle for a pharmacy is therefore clear: clean surfaces as usual first, then run the UV-C unit to disinfect the entire shop after closing, when nobody is inside.
⚠️ Safety first: UV-C light is harmful to eyes and skin, and ozone irritates the airways. Never run the unit with people, pets or plants in the room. Use the timer and leave before the unit starts. After it stops, open doors to ventilate before re-entering, and follow the manufacturer's manual strictly.
What UV-C can and cannot do
Dr. Nan is a scientist by training, so before buying she wanted to understand both the strengths and the limits of UV-C. That honesty also helped her explain it accurately to customers.
What it does well
- Inactivates a broad range of microbes — bacteria, viruses and fungal spores — on exposed surfaces and in the air passing near the lamp.
- Leaves no liquid residue, which matters in a shop full of packaged products and paper labels.
- Reaches surfaces people forget, such as the tops of shelves, the backs of display stands and the ceiling-facing side of hanging signs.
- Adds consistency: once the timer is set, the cycle runs the same way every night, regardless of who closed the shop.
Its limits
- Line of sight matters. Areas in shadow — inside closed drawers, behind boxes, under the counter — receive little or no light. The ozone component helps, but placement still matters.
- Dirt blocks light. Dust and grime shield microbes, so cleaning must come first.
- Distance reduces dose. Surfaces far from the lamp receive less energy than those nearby, which is why the unit should sit centrally and run for the right time.
- Strictly unoccupied use. Its power to damage microbes is the same reason it must never be used around people.
Understood this way, UV-C becomes what it should be: a reliable extra layer of protection on top of good cleaning and sensible daytime habits, not a magic replacement for them.
Planning placement in a small shop
Dr. Nan's pharmacy is a narrow shophouse, about four metres wide and five deep, with shelving on both side walls, a dispensing counter at the back and a small consultation corner. To get the most from each cycle, she mapped the shop and made a few simple decisions.
- Central position. The unit sits on a stool in the middle aisle, roughly equidistant from both shelving walls and the counter.
- Open what you want treated. The drawer under the cash register, the consultation-room door and the glass display case are left open during the cycle.
- Protect what should stay dark. Light-sensitive stock lives in an opaque cabinet that remains closed, and a cloth covers the clear-fronted display of herbal products.
- A second position on busy weeks. During outbreaks, she runs one cycle with the unit in the aisle and a second, shorter cycle with it placed on the dispensing counter, to give the most-touched area a higher dose.
- A log on the wall. A simple sheet records the date, cycle time and initials, so the routine never depends on memory.
These small adjustments took ten minutes to plan and made each night's cycle noticeably more thorough. The same thinking applies to any small clinic, office or shop: map the space, find the shadows, and place the unit where it can see the most.
10 reasons pharmacies choose the MASTER UV-C 996
- Disinfects surfaces and air — UV-C light plus ozone covers the whole room.
- No liquids, so no chemical residue on medicine boxes and products.
- Works after closing, without disrupting service during opening hours.
- Built-in timer so you can switch it on and leave safely.
- Compact and portable, ideal for small shophouses.
- Helps remove stale odours from a shop air-conditioned all day.
- Energy-efficient at 38 watts, with very low running cost per cycle.
- Complements existing cleaning, reducing germs in places wiping may miss.
- Multi-room use: consultation room, stockroom and staff room.
- Builds community confidence: the pharmacy can say it disinfects every night before opening.
Dr. Nan's new routine
During the day
- Hand sanitiser at the door and counter, with a sign asking coughing customers to wear a mask.
- A free mask for any coughing customer who doesn't have one.
- Regular wiping of the counter, card machine and pens with Chemgene HLD4H disinfectant, especially after customers with respiratory symptoms.
- Waiting chairs spaced further apart, and the front door opened for ventilation when weather allows.
Every night after closing
- Clean high-touch surfaces and mop the floor.
- Open cabinets and drawers that need disinfecting and place the MASTER UV-C 996 in the centre of the shop where light spreads widely.
- Store light-sensitive products — such as medicines in clear packaging — in opaque cabinets or cover them before switching on.
- Set the timer, leave, lock up and hang a "Disinfection in progress — do not enter" sign.
- Next morning, open the door to ventilate before restocking.
During outbreaks
- Add a midday cycle in the private consultation room while it is closed and empty.