Last updated: 25 Sep 2026 | 8 Views |
When a committee must choose a ULV cold fogger from several bids, decisions based on feel or familiarity with a previous brand lead to endless debate and weak answers for auditors. This article offers a technical scoring matrix that Offices of Disease Prevention and Control (ODPC) and Provincial Public Health Offices can adapt immediately, plus a worked example of reading the published information for the electric AIROFOG U260 ULV sprayer against the criteria, using only what the supplier states.
Kittipong is a public health technical officer working on vector-borne disease control at a provincial health office. This year he was appointed to a committee reviewing bids for ULV sprayers to be used indoors at several service units across the province: community hospitals, office buildings and laboratories.
The bids covered several models, and every supplier wrote its documents differently. One stated a clear droplet size range; another said only "extra-fine mist"; a third attached several certificates without showing which model they covered. In the meeting, one member insisted motor power mattered most, another focused on weight, and a third had used one brand before and simply felt more comfortable with it.
The meeting ran for hours without a conclusion. Everyone was right from their own angle, but nobody had a tool to line those opinions up systematically. Finally the chair asked Kittipong to build a scoring matrix the whole committee could share, and one that could show an auditor exactly which evidence stood behind every score.
The matrix in this article is a starting point that teams like Kittipong's can use, adjusting the weights to their own mission.
Health: Aedes mosquitoes carry dengue, chikungunya and Zika, and Anopheles mosquitoes carry malaria. Health facilities hold feverish patients, children, older people and pregnant women, all of whom need extra protection. A machine with unsuitable droplets or frequent breakdowns weakens indoor control of adult mosquitoes.
Budget: equipment bought at provincial or regional level is often distributed to many units. Choose the wrong model and the mistake multiplies across every unit that receives it, in repairs, parts and lost time.
Credibility: ODPCs and provincial health offices are technical role models for district and subdistrict units. Their selection criteria are often reused downstream. The clearer and more evidence-based the criteria, the more the office serves as a technical anchor for its network.
Audit: a decision explained only as "the committee considered it better" is weak when another bidder complains. A matrix tying every score to a document lets you answer with evidence.
Workload: with shared criteria, the committee stops re-arguing the same points each meeting, and the office can reuse the matrix in the next procurement round.
The core idea is that every criterion uses the same scale and is scored on both strength of evidence and fit to the task. This stops a well-written bid with no documents from gaining an advantage.
| Score | Meaning |
|---|---|
| 0 | No information, or information that does not meet the office's need |
| 1 | A claim without figures or supporting documents |
| 2 | Figures in product literature, but no certificate or demonstration yet |
| 3 | Complete, model-specific documents consistent with the office's task |
| 4 | Complete documents confirmed by a demonstration or test before the committee |
The weighted score for each criterion is simply (score divided by 4) multiplied by that criterion's weight. Add all criteria for a total out of 100.
A quick example of the arithmetic: if a bid scores 3 on a criterion weighted 12, it earns three quarters of 12, which is 9 points. If it scores 2 on a criterion weighted 8, it earns half of 8, which is 4 points. Because the calculation is so simple, any committee member can check it by hand, and the evaluation file does not depend on a spreadsheet that only one person understands. The same scale also makes it easy to see where a bid can improve its score, since the answer is almost always "provide the document" or "show us in a demonstration", which keeps the process transparent for every bidder.
These weights are an example for indoor spraying in health facilities and government buildings. They are not an official standard. The committee should adjust them to its mission and fix them before any bid is opened.
| Group / criterion | Weight | Evidence requested |
|---|---|---|
| A. Spraying performance (35) | ||
| A1 Droplet size range stated numerically and suited to indoor adult mosquito control | 12 | Product literature stating the micron range |
| A2 Adjustable nozzle or flow | 8 | Manual and live adjustment demo |
| A3 Drive power and power source suited to the site | 8 | Motor spec and power type |
| A4 Supports the chemical formulations the office uses | 7 | Product data or bidder's written confirmation |
| B. Safety and site fit (20) | ||
| B1 Operates without heat or flame, suited to indoor use | 8 | Operating principle documentation |
| B2 Manufacturer states suitability for health or high-safety sites | 6 | Product literature |
| B3 Ease of use, weight and handling for operators | 6 | Weight spec and hands-on trial |
| C. Quality and evidence (20) | ||
| C1 Origin and manufacturer clearly identified | 5 | Origin documentation |
| C2 Supplier operates a quality management system | 5 | Copies of quality certificates |
| C3 Quality inspection before delivery | 5 | Written confirmation of inspection process |
| C4 Certificates cited match the model offered | 5 | Model-specific certificate copies |
| D. After-sales service (25) | ||
| D1 Clear warranty terms | 6 | Warranty letter |
| D2 Technicians in Thailand | 6 | Contact channels and repair process |
| D3 Spare parts availability | 6 | Written spare-parts commitment |
| D4 Operator training | 4 | Training plan |
| D5 Thai-language manual | 3 | Sample manual |
| Total | 100 | |
Important: this is a technical evaluation tool. Using scores within procurement, for example combined with price, must follow the criteria and methods in the regulations currently in force, and the criteria must be announced in advance through the proper process.
This section shows how to use the matrix by matching the supplier's published information on the AIROFOG U260 ULV cold fogger to each criterion. Actual scores must be given by the committee after checking documents and watching a demonstration; this article does not assign them.
| Criterion | What the supplier states | What the committee should request |
|---|---|---|
| A1 Droplet size | 15 to 30 micron droplets | The product document stating this figure, plus a spraying demo |
| A2 Nozzle adjustment | Adjustable nozzle | Adjustment instructions and a live demo |
| A3 Power | Electric, 800 W motor | Power supply type and cable length |
| A4 Chemical formulations | Not stated in the summary used for this article | Written confirmation of supported formulations |
| B1 No heat | Electric ULV sprayer | Operating principle documentation |
| B2 Site suitability | Stated for hospitals, laboratories and high-safety sites | Supporting product literature |
| B3 Weight and handling | Not stated in the summary used for this article | Weight, tank capacity and a hands-on trial |
| C1 Origin | Germany | Origin documentation |
| C2 and C3 Quality systems | WHD holds ISO and GMP and inspects 100% before delivery | Certificate copies and written confirmation |
| D1 to D5 After-sales | WHD provides after-sales service, technicians and spare parts | Warranty letter, training plan and Thai manual |
The published information addresses several criteria in groups A, B and C. For items the summary does not cover, such as chemical formulations, weight and tank capacity, the committee should request documents before scoring. Apply exactly the same approach to every bid, for fairness.
Show group subtotals before the total. Four separate subtotals reveal where each bid is strong or weak; one may perform well but have weak after-sales support, a long-term risk for the network.
Set minimum scores per group. Beyond the total, the committee can agree in advance that certain groups must reach a threshold, preventing a high total from hiding a serious weakness such as no local technicians.
Attach evidence for every 3 or 4. These scores claim full documents or a demonstration. If no evidence is attached, lower the score according to the scale.
Record disagreements. Where members scored very differently, note each side's reasoning and the agreed outcome. This is valuable when questions come later.
Keep the matrix for next time. After a period of real use, let the health team review which criteria deserve more or less weight, so the matrix improves and becomes a shared tool for the network.
The example weights assume indoor spraying in health facilities. Offices with other priorities can shift weight between groups while keeping the total at 100. The guidance below is qualitative on purpose; the committee decides the exact figures and records its reasons before bids are opened.
| Mission profile | Consider more weight on | Why |
|---|---|---|
| Hospital wards and waiting areas | B1 no heat, B2 site suitability | Vulnerable patients and sensitive equipment nearby |
| Laboratories and insectaries | A1 droplet size, A2 nozzle control | Precise, controllable application in enclosed rooms |
| Equipment shared across many district units | Group D after-sales, D4 training | Many operators and locations increase the need for support |
| Rapid response teams | B3 handling, A3 power source | Frequent transport and set-up in varied buildings |
Whatever profile you choose, keep the same 0 to 4 evidence scale. Changing weights changes priorities; changing the scale would change the meaning of every score and make comparisons across procurement rounds unreliable. A stable scale is what allows provincial offices to share results with ODPCs and with each other, building a body of evidence about which government mosquito control equipment performs well in real Thai conditions over time.
It also helps to document why a profile was chosen. A short paragraph in the evaluation file, noting the sites the machines will serve and the vulnerable groups present, lets reviewers understand the weights without needing to attend the meeting.
The AIROFOG U260 is an electric ULV cold fogger from Germany with an 800 W motor, an adjustable nozzle and droplets in the 15 to 30 micron range. The supplier states it is suited to hospitals, laboratories and high-safety sites, which matches the work of ODPCs and provincial health offices responsible for health service buildings, offices and laboratories in their networks.
Its key technical strengths are that it is electric and uses no heat, making it more suitable indoors than a thermal fogger, and that its droplet range is stated numerically, so criterion A1 can be scored from documents rather than description. Combined with World Health Disinfection (WHD)'s ISO and GMP systems, 100% quality control before delivery, after-sales service, technicians, spare parts and documentation aligned with Thai government equipment standards, the bid has evidence behind many criteria in the matrix.
For outdoor or wide-area work, evaluate other machine types separately, such as the AIROFOG AT35 thermal fogging machine or the GREENFOG F4 vehicle-mounted sprayer, with weights adjusted for that work.
Fix criteria before seeing bids. Record weights and the scale before bids are opened, to avoid any suspicion of tailoring criteria to one bidder.
Align specifications with the criteria. If droplet size matters, require bidders to state a numeric range with documents, without fixing figures that match only one brand.
List required documents clearly: product literature, certificate copies, warranty letter, training plan and a sample Thai manual, so every bid arrives in comparable form.
Budget for the whole cycle: chemicals, protective equipment and maintenance, in line with how network units will use the machines.
Check current regulations. Ask procurement staff to confirm that using scores in the decision follows the criteria in force on the day.
"Before the matrix, we argued about which model was better based on personal experience. Once we scored by evidence level, agreement came much faster. A bid with a numeric droplet range, documents and a live nozzle demonstration scored accordingly; a bid with only descriptions was asked for documents before scoring. We can now explain every line to management and auditors."
Note: a composite example based on typical technical committee work, not a quote from any specific person or agency.
Q: Are these weights an official government standard?
A: No. They are an example for indoor spraying. Committees should adjust them to their mission and fix them in advance.
Q: What if a bidder does not state droplet size?
A: Score according to the evidence available, 0 or 1. If rules allow further document requests, make the same request of every bidder.
Q: Can this matrix evaluate thermal foggers?
A: The structure works, but adjust criteria and weights, for example adding heat resistance of materials and outdoor use.
Q: Where does the U260 information come from?
A: From the supplier's published information: German origin, electric ULV, 800 W motor, adjustable nozzle and 15 to 30 micron droplets. Request other details directly from the supplier.
Q: Can we request a U260 demonstration?
A: Contact 065-556-6294 or LINE @whd268 to arrange one.
Q: Does a ULV sprayer treat dengue?
A: No. It reduces adult mosquitoes and transmission risk only; prevention needs several measures together.
Request documents, specifications and a demonstration of the AIROFOG U260 for public health use.
See AIROFOG U260 products and prices, click hereCall 065-556-6294 · LINE @whd268
Visit the WHD government equipment hub#MosquitoFogger #MosquitoSprayer #ULVColdFogger #VectorControl #PublicHealth #GovernmentMosquitoControl #AIROFOGU260
Keywords: mosquito fogger, mosquito sprayer, thermal fogging machine, ULV cold fogger, government mosquito control equipment, vector control, evaluation criteria, scoring matrix, ODPC, provincial health office, AIROFOG U260